Answer a few questions about your home or business. We run a cooling load estimate based on the ACCA Manual J method and tell you the system size the space actually needs. Already have a quote? Get it checked for $39.

Pre-filled with an example: a 2,200 sq ft, two-story home on Long Island. Change anything and the result updates instantly.
The space
What are you cooling?
Sets the summer design temperature and humidity for your area.
Insulation and air leaks
How well insulated is it?
Not sure? Use the age of the building. Upgraded attic insulation counts as one step better.
How drafty is it?
Windows and sun
Quote Check

Got a quote? Find out if it's the right size and a fair price.

Upload your contractor's quote. We compare it against the load calculation above, check the price and equipment, and list exactly what to ask before you sign.

  1. Upload a photo or PDF of your quote.
  2. Answer the questions above about your home.
  3. Get your report in minutes, on screen and by email.
$39one quote · $10 each extra
Sample report · example quote

Quote Check for an example quote

Example Heating & CoolingCentral AC replacementHicksville, NY 11801Checked against your answers above

1. Size

Quoted4 tons
Your calculated load
Right-size range

2. Price

Above typical
Quoted total$13,900
Price per ton$3,475
Typical for this tier$2,600–$3,200

The price per ton runs about 10–30% above what we see for a 16 SEER2 system of this type. If the size drops, the total should drop too. Ask for an itemized price before negotiating.

Example figures for illustration. The live product compares against real quotes collected in your area.

3. Equipment

Looks right
  • ✓Outdoor unit and indoor coil are a certified matched pair
  • ✓16 SEER2 efficiency, above the federal minimum
  • ✓Uses the new required low-impact refrigerant
  • !10-year parts warranty only if registered within 60 days
  • !Labor warranty: 1 year, shorter than the 2–10 years many installers offer

4. What's missing from the quote

4 items
  • ✗Manual J load calculation
  • ✗Duct sealing or leakage test
  • ✗Startup testing (refrigerant charge, airflow)
  • ✗Building permit
  • ✓Removal and disposal of old unit
  • ✓New refrigerant line set
  • ✓Thermostat
  • ✓Electrical disconnect

5. Rebates you may be leaving on the table

Check eligibility

Long Island homeowners may qualify for PSEG Long Island efficiency rebates, and for NYS Clean Heat incentives if they switch to a heat pump. Clean Heat requires a Manual J with every application, which is one more reason to ask for one.

6. Questions to send this contractor

Ready to send

    Want a second opinion?

    Get a quote from a RightSizeAC Verified contractor who runs a Manual J on site and gives you the report.

    Why oversizing costs you

    A bigger unit costs more up front, then short-cycles: it cools the air fast and shuts off before pulling moisture out. You get a clammy house, uneven rooms and more wear.

    What a load calculation measures

    Heat soaking through walls and the roof, sun through windows, outside air leaking in, people and appliances, and ducts in hot spaces. Square footage alone says almost nothing about any of these.

    How to use this number

    Bring it to every quote. If someone proposes a size more than half a ton above it, ask to see their Manual J report. A contractor who did one will have it.

    Your size
    2.5 tons